MicroCraft TDR飛針測試機 HTA2525

Equipped with built-in full automation

Equipped with built-in full automation

Specifications
Max. Test Area 9.8 x 9.8″ (250x250mm)
Min. Board Size 2.4 x 3.1″ (60x80mm)
Max. Board Thickness 0.06″ (1.6mm)
Clamp System Vacuum Style
Max. Stack 50pc (based on thickness of 1.6mm)
Rotate Radius 360°
Repeatable Accuracy X-Y ±0.4mil (±10µm)
Repeatable Accuracy θ
Impedance Accuracy*1 50Ω±1%
Air N/A
Power Supply Three Phase AC200V 50/60Hz
AC220V 60Hz 8A (including vacuum pump)
Weight 529lbs. (240kg)*2
Dimensions Dimensions
*1 Calibration allows room temperature variation of ±2°C.
*2 Machine: 441lbs.(200kg), Vacuum pump: 88lbs.(40kg)
Common System Requirements
System Requirements 1) Control PC & Monitor
2) Meter

  • [ Tektronix ] DSA8300, DSA8200, TDS8000, 11801B/C
  • [ Keysight Technologies (formerly Agilent Technologies) ] E5063A option TDR, E5071C+ENA option TDR, 86100A/B/C, 54750
  • [ Teledyne LeCroy ] WaveExpert100H+ST-20
  • [ MicroCraft ] MZPC30/50

Please contact our sales for details. Meters to be purchased separately.

Operating condition · Operating temperature: 0-+40°C.,
· Storing temperature: 0-+50°C.,
No condensation, dust, vibration nor any corrosive gas
· Atmospheric Dew Point: -14°C or below (at 0.7Mpa, dew point is 15°C or below)
· Oil Mist Concentration: 1mg/㎥ (ANR) or below